Product Model |
Picture |
Parameter Explanation |
Download |
CV 4-4000/SP2 |
|
CV 4-4000/SP2 --CV 4-4000/SP2
Ouput Relay Type : Instantaneous
Technology : C-Type
Measurement : Voltage
Primary Nominal Value : 2800 V
Accuracy : 0.4 %
Mounting : -
Measuring Range : 4000 V
Supply Voltage : 24 - 24
Supply voltage type Bipolar
Secondary Signal : 70 mA
|
|
CV 4-4000/SP1 |
|
CV 4-4000/SP1--CV 4-4000/SP1
Ouput Relay Type : Instantaneous
Technology : C-Type
Measurement : Voltage
Primary Nominal Value : 2800 V
Accuracy : 0.4 %
Mounting : -
Measuring Range : 4000 V
Supply Voltage : 24 - 24
Supply voltage type Bipolar
Secondary Signal : 7000 mV
|
|
CV 4-4000 |
|
CV 4-4000 --CV 4-4000
Ouput Relay Type : Instantaneous
Technology : C-Type
Measurement : Voltage
Primary Nominal Value : 2828 V
Accuracy : 1 %
Mounting : -
Measuring Range : 4000 V
Supply Voltage : 15 - 15
Supply voltage type Bipolar
Secondary Signal : 7070 mV
|
|
LV 200-AW/2/6400 |
|
LV 200-AW/2/6400--LV 200-AW/2/6400
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 6400 V
Accuracy : 1 %
Mounting : -
Measuring Range : 9600 V
Supply Voltage : 15 - 24
Supply voltage type Bipolar
Secondary Signal : 80 mA
|
|
LV 200-AW/2/3200 |
|
LV 200-AW/2/3200--LV 200-AW/2/3200
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 3200 V
Accuracy : 1 %
Mounting : -
Measuring Range : 4800 V
Supply Voltage : 15 - 24
Supply voltage type Bipolar
Secondary Signal : 80 mA
|
|
LV 200-AW/2/1600 |
|
LV 200-AW/2/1600--LV 200-AW/2/1600
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1600 V
Accuracy : 1 %
Mounting : -
Measuring Range : 2400 V
Supply Voltage : 15 - 24
Supply voltage type Bipolar
Secondary Signal : 80 mA
|
|
LV 25-1200 |
|
LV 25-1200--LV 25-1200
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1200 V
Accuracy : 0.8 %
Mounting : -
Measuring Range : 1800 V
Supply Voltage : 12 - 15
Supply voltage type Bipolar
Secondary Signal : 25 mA
|
|
LV 25-1000 |
|
LV 25-1000--LV 25-1000
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1000 V
Accuracy : 0.8 %
Mounting : -
Measuring Range : 1500 V
Supply Voltage : 12 - 15
Supply voltage type Bipolar
Secondary Signal : 25 mA
|
|
LV 100-2000 |
|
LV 100-2000 --LV 100-2000
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 2000 V
Accuracy : 0.7 %
Mounting : -
Measuring Range : 3000 V
Supply Voltage : 15 - 15
Supply voltage type Bipolar
Secondary Signal : 50 mA
|
|
LV 100-1500 |
|
LV 100-1500--LV 100-1500
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1500 V
Accuracy : 0.7 %
Mounting : -
Measuring Range : 2250 V
Supply Voltage : 15 - 15
Supply voltage type Bipolar
Secondary Signal : 50 mA
|
|
LV 100-1200 |
|
LV 100-1200--LV 100-1200
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1200 V
Accuracy : 0.7 %
Mounting : -
Measuring Range : 1800 V
Supply Voltage : 15 - 15
Supply voltage type Bipolar
Secondary Signal : 50 mA
|
|
LV 100-1000 |
|
LV 100-1000 --LV 100-1000
Ouput Relay Type : Instantaneous
Technology : Closed loop Hall Effect
Measurement : Voltage
Primary Nominal Value : 1000 V
Accuracy : 0.7 %
Mounting : -
Measuring Range : 1500 V
Supply Voltage : 15 - 15
Supply voltage type Bipolar
Secondary Signal : 50 mA
|
|