MS-HIB50 Current Transducer--MS-HIB50
Product Introduction:
Current Transducer is a that, has been measured current non-anamorphic transfer to measurement module of output current in term of linearity proportion, primary side、secondary side high insulation, isolation measurement non-insert ullage, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Current of primary side measurement range: 0-75A (0…100KHz)
Transform Rate: 1 : 1000
Measurement Accuracy: 0.8% & 0.5%
Linearity Accuracy: ≤0.2%
Response Time: tr ≤ 1μS@100% of IpMAX
Current Malajustment: IO≤±0.2mA @TA=25℃
Error of stagnant magnetism: IOM≤±0.1mA @IP=0A
Temperature excursion: IO≤0.020%/℃
Ability of cincture record: RM=0-200Ω
Compression resistance of work frequency: input/output/crust AC3.0KV;1mA /min
Power supply consume: output current±25mA (power supply DC±15V)
MS-HIB100
MS-HIB100 Current Transducer--MS-HIB100
Product Introduction:
Current Transducer is a that, has been measured current non-anamorphic transfer to measurement module of output current in term of linearity proportion, primary side、secondary side high insulation, isolation measurement non-insert ullage, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Current of primary side measurement range: 0-150A (0…100KHz)
Transform Rate: 1 : 2000
Measurement Accuracy: 0.8% & 0.5%
Linearity Accuracy: ≤0.2%
Response Time: tr ≤ 1μS@100% of IpMAX
Current Malajustment: IO≤±0.2mA @TA=25℃
Error of stagnant magnetism: IOM≤±0.1mA @IP=0A
Temperature excursion: IO≤0.020%/℃
Ability of cincture record: RM=0-150Ω
Compression resistance of work frequency: input/output/crust AC3.0KV;1mA /min
Power supply consume: output current±30mA (power supply DC±15V)
MS-HIB200/SP1
MS-HIB200/SP1 Current Transducer--MS-HIB200/SP1
Product Introduction:
Current Transducer is a that, has been measured current non-anamorphic transfer to measurement module of output current in term of linearity proportion, primary side、secondary side high insulation, isolation measurement non-insert ullage, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Current of primary side measurement range: 0-300A (0…100KHz)
Transform Rate: 1 : 2000
Measurement Accuracy: 0.5%
Linearity Accuracy: ≤0.1%
Response Time: tr ≤ 1μS@100% of IpMAX
Current Malajustment: IO≤±0.2mA @TA=25℃
Error of stagnant magnetism: IOM≤±0.1mA @IP=0A
Temperature excursion: IO≤0.020%/℃
Ability of cincture record: RM=0-75Ω
Compression resistance of work frequency: input/output/crust AC3.0KV;1mA /min
Power supply consume: output current±30mA (power supply DC±15V)
MS-HIB200
MS-HIB200 Current Transducer--MS-HIB200
Product Introduction:
Current Transducer is a that, has been measured current non-anamorphic transfer to measurement module of output current in term of linearity proportion, primary side、secondary side high insulation, isolation measurement non-insert ullage, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Current of primary side measurement range: 0-300A (0…100KHz)
Transform Rate: 1 : 2000
Measurement Accuracy: 0.8% & 0.5%
Linearity Accuracy: ≤0.2%
Response Time: tr ≤ 1μS@100% of IpMAX
Current Malajustment: IO≤±0.2mA @TA=25℃
Error of stagnant magnetism: IOM≤±0.1mA @IP=0A
Temperature excursion: IO≤0.020%/℃
Ability of cincture record: RM=0-75Ω
Compression resistance of work frequency: input/output/crust AC3.0KV;1mA /min
Power supply consume: output current±30mA (power supply DC±15V)