MS-I1 Single Phase Current TransmitterMS-I1 Single Phase Current Transmitter--MS-I1
Product Introduction:
Alternating current transmitter is a that, has been measured alternatng current transfer to measurement module of output direct current or direct voltage in term of linearity proportion, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Measurement range: AC0-15A
Measurement Accuracy: 0.5% & 0.2%
Linearity Accuracy: ≤0.1%
Response Time: tr ≤ 300ms
Over loading ability: 10 times rating 1 second
Ability of cincture record: voltage output:RL≥5KΩ
current output:RL≤300Ω
Width of narrowband: DC…20KHz
Compression resistance of work frequency: input/output/crust AC2.5KV;1mA /min
Isolation intensity: ≥20MΩ(DC500V)
Power use of whole machine: ≤1.2VA(power supplyDC24V)
Execution standard: GB/T13850-1998idt IEC688:1992
MS-JIA
MS-JIA Single Phase Current Transmitter--MS-JIA
Product Introduction:
Alternating current transmitter is a that, has been measured alternatng current transfer to measurement module of output direct current or direct voltage in term of linearity proportion, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Measurement range: AC0-45A
Measurement Accuracy: 0.5% & 0.2%
Linearity Accuracy: ≤0.1%
Response Time: tr ≤ 300ms
Over loading ability: 10 times rating 1 second
Ability of cincture record: voltage output:RL≥5KΩ
current output:RL≤300Ω
Width of narrowband: DC…20KHz
Compression resistance of work frequency: input/output/crust AC2.5KV;1mA /min
Isolation intensity: ≥20MΩ(DC500V)
Power use of whole machine: ≤1.2VA(power supplyDC24V)
Execution standard: GB/T13850-1998idt IEC688:1992
MS-TJIB100
MS-TJIB100 Alternating Current Transmitter--MS-TJIB100
Product Introduction:
Alternating current transmitter is a that, has been measured alternatng current transfer to measurement module of output direct current or direct voltage in term of linearity proportion, high precision degree, high linearity degree, high integration degree, little cubage, simple configuration, tranquilization of long-term work and suit in variety of work environment.
Current Reference:
Measurement range: AC0-150A
Measurement Accuracy: 0.5%
Linearity Accuracy: ≤0.2%
Response Time: tr ≤ 300ms
Over loading ability: 10 times rating 60 second
Ability of cincture record: voltage output:RL≥5KΩ
current output:RL≤300Ω
Width of narrowband: DC…20KHz
Compression resistance of work frequency: input/output/crust AC2.5KV;1mA /min
Isolation intensity: ≥20MΩ(DC500V)
Power use of whole machine: ≤1.2VA(power supplyDC24V)
Execution standard: GB/T13850-1998idt IEC688:1992